Elevator Specifications & Model Details

  • Number of Stops: 3-Stops
  • Maximum Travel Distance: 35 ft
  • Number of Passengers: 2 Passengers
  • Rated Load: 450 lbs
  • External Cube Dimensions: 36” x 36” inches
  • Cube Height: 92” inches
  • Rated Load: 400 lbs
  • Speed: 40 fpm
  • Minimum Floor to Floor Clearance: 92”
  • Minimum Floor to Ceiling Clearance: 81”
  • Minimum Overhead Clearance:
    • Standard Head Unit Machinery: 107”
    • Split-Unit Remote Machinery: 97”
  • Through-Floor Penetration Required: 38” x 38”
  • No Pit Required: Bottom Floor Must Be 100% Level As Elevator Rests On Existing Floor
  • Entrance Width Opening: 25”
  • Internal Cabin Height: 79”
  • Internal Cabin Dimensions: 32” x 32”
  • Automatic LED Lighting & Cabin Fan
  • Door Openings
    • Same-Side (In-Line)
    • Opposite Side (Pass-Through)
    • 90° Degree Openings
  • All Doors Are Hinged On Top Left With Door Swinging To The Left From Inside The Cabin:
    • Door Height: 77” 3/4
    • Door Height with Door Closer: 79” 1/2
  • Each Landing Specified Will Include Only One Door.
  • 24V Electrical Circuits With al Controls In Cabin.
  • Push Button Call Controls with Precise Leveling At Each Landing
  • 220-240V, 60/50 Hz, 30 amp single phase power supply
  • L1, L2, Ground
  • 5 Turbine motors located in pump
  • Primary disconnect to be provided by the homeowner
  • Electrical receptacle is at top of elevator. If a split unit is used, electrical receptacle will be on top of head / split system
  • If installing a phone line, a phone jack is to be provided near the power supply line but isolated.
  • 4 ft power cord and plug is provided on top of elevator or head/split system for ease of connecting. The provided plug is manufactured by Pass & Seymour or comparable substitute.
  • Elevator can be hardwired directly to primary disconnect as per local jurisdiction building/electrical code requirements.
  • Homeowner / electrician needs to provide 220-240V, single phase, 30 amp electrical outlet Safety Details
  • Automatic descent to ground level at safety speed in the event of power failure.
  • Mechanical emergency brakes engage within two inches of freefall in vacuum loss or catastrophic failure.
  • Electromechanical interlocks at each landing.
  • Alarm system & telephone

Please find the attached drawings, specifications, and installation requirements for your convenience. We appreciate your interest in The Cube and look forward to being apart of your project

Contact Us Today If Additional Information Is Required